Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Am J Bioeth ; 24(2): 69-90, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37155651

RESUMO

Psychiatry is rapidly adopting digital phenotyping and artificial intelligence/machine learning tools to study mental illness based on tracking participants' locations, online activity, phone and text message usage, heart rate, sleep, physical activity, and more. Existing ethical frameworks for return of individual research results (IRRs) are inadequate to guide researchers for when, if, and how to return this unprecedented number of potentially sensitive results about each participant's real-world behavior. To address this gap, we convened an interdisciplinary expert working group, supported by a National Institute of Mental Health grant. Building on established guidelines and the emerging norm of returning results in participant-centered research, we present a novel framework specific to the ethical, legal, and social implications of returning IRRs in digital phenotyping research. Our framework offers researchers, clinicians, and Institutional Review Boards (IRBs) urgently needed guidance, and the principles developed here in the context of psychiatry will be readily adaptable to other therapeutic areas.


Assuntos
Transtornos Mentais , Psiquiatria , Humanos , Inteligência Artificial , Transtornos Mentais/terapia , Comitês de Ética em Pesquisa , Pesquisadores
2.
World Neurosurg ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37979684

RESUMO

BACKGROUND: Hereditary hemochromatosis (HH) is a common autosomal recessive disorder. This disease affects gut iron transport, leading to iron overload, which affects immune function, coagulation mechanics, and bone health. Within the spine, HH contributes to decreased bone mineral density and accelerated intervertebral disc degeneration. The purpose of this study was to discover the differences in the rates of common 90-day postoperative complications and 1-year and 2-year surgical outcomes in patients with and without HH after anterior cervical discectomy and fusion (ACDF). METHODS: Using the PearlDiver database, patients with active diagnoses of HH before ACDF were matched to patients without HH using a 1:5 ratio on the basis of age, sex, body mass index, and comorbidities. Postoperative complications were assessed at 90 days, and 1-year and 2-year surgical outcomes were assessed. All outcomes and complications were analyzed using multivariate logistic regression with significance achieved at P < 0.05. RESULTS: Patients with HH had significantly higher rates of 1-year and 2-year reoperation rates compared with patients without HH (29.19% vs. 3.94% and 37.1% vs. 5.93%, respectively; P < 0.001). The rates of 90-day postoperative complications significantly increased in patients with HH including dysphagia, pneumonia, cerebrovascular accident, deep vein thrombosis, acute kidney injury, urinary tract infection, hyponatremia, surgical site infection, iatrogenic deformity, emergency department visit, and hospital readmission. CONCLUSIONS: Patients with HH undergoing ACDF showed increased 90-day postoperative complications and significantly increased rates of 1-year and 2-year reoperation compared with patients without HH. These findings suggest that iron overload may contribute to adverse outcomes in patients with HH undergoing 1-level and 2-level ACDF.

3.
Nat Rev Bioeng ; 1(9): 617-630, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37705717

RESUMO

The advent of portable, low-field MRI (LF-MRI) heralds new opportunities in neuroimaging. Low power requirements and transportability have enabled scanning outside the controlled environment of a conventional MRI suite, enhancing access to neuroimaging for indications that are not well suited to existing technologies. Maximizing the information extracted from the reduced signal-to-noise ratio of LF-MRI is crucial to developing clinically useful diagnostic images. Progress in electromagnetic noise cancellation and machine learning reconstruction algorithms from sparse k-space data as well as new approaches to image enhancement have now enabled these advancements. Coupling technological innovation with bedside imaging creates new prospects in visualizing the healthy brain and detecting acute and chronic pathological changes. Ongoing development of hardware, improvements in pulse sequences and image reconstruction, and validation of clinical utility will continue to accelerate this field. As further innovation occurs, portable LF-MRI will facilitate the democratization of MRI and create new applications not previously feasible with conventional systems.

4.
J Neurosurg Case Lessons ; 5(11)2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36916526

RESUMO

BACKGROUND: The use of carbon fiber or polyetheretherketone spine constructs has proven to be a safe and effective alternative to standard metal alloy. The mechanical properties of carbon fiber while unique provide a construct that is comparable in strength to previous titanium-based constructs and have additionally shown greater fatigue resistance. These constructs have been especially useful for the mechanical stabilization of the spine following tumor resection. The subsequent interference seen when imaging a patient with a traditional metallic construct is reduced and allows for improved tumor surveillance after the procedure, and a more accurate delivery of radiotherapy when indicated. OBSERVATIONS: This case report details the treatment of a 25-year-old female diagnosed with a sacral giant cell tumor. The authors discuss the use of a carbon fiber-reinforced polyetheretherketone for lumbopelvic reconstruction. LESSONS: Carbon fiber-reinforced polyetheretherketone with its radiolucency and rigidity is a reliable option for complex spinal reconstruction after tumor resection.

5.
J Neurosurg Spine ; 38(3): 313-318, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36683188

RESUMO

OBJECTIVE: The two most common revision options available for the management of loose pedicle screws are larger-diameter screws and cement augmentation into the vertebral body for secondary fixation. An alternative revision method is impaction grafting (pedicoplasty) of the failed pedicle screw track. This technique uses the impaction of corticocancellous bone into the pedicle and vertebral body through a series of custom funnels to reconstitute a new pedicle wall and a neomedullary canal. The goal of this study was to compare the biomechanics of screws inserted after pedicoplasty (impaction grafting) of a pedicle defect to those of an upsized screw and a cement-augmented screw. METHODS: For this biomechanical cadaveric study the investigators used 10 vertebral bodies (L1-5) that were free of metastatic disease or primary bone disease. Following initial screw insertion, each screw was subjected to a pullout force that was applied axially along the screw trajectory at 5 mm per minute until failure. Each specimen was instrumented with a pedicoplasty revision using the original screw diameter, and on the contralateral side either a fenestrated screw with cement augmentation or a screw upsized by 1 mm was inserted in a randomized fashion. These revisions were then pulled out using the previously mentioned methods. RESULTS: Initial screw pullout values for the paired upsized screw and pedicoplasty were 717 ± 511 N and 774 ± 414 N, respectively (p = 0.747) (n = 14). Revised pullout values for the paired upsized screw and pedicoplasty were 775 ± 461 N and 762 ± 320 N, respectively (p = 0.932). Initial pullout values for the paired cement augmentation and pedicoplasty were 792 ± 434 N and 880 ± 558 N, respectively (p = 0.649). Revised pullout values for the paired cement augmentation and pedicoplasty were 1159 ± 300 N and 687 ± 213 N, respectively (p < 0.001). CONCLUSIONS: Pedicle defects are difficult to manage. Reconstitution of the pedicle and creation of a neomedullary canal appears to be possible through the use of pedicoplasty. Biomechanically, screws that have been used in pedicoplasty have equivalent pullout strength to an upsized screw, and have greater insertional torques than those with the same diameter that have not been used in pedicoplasty, yet they are not superior to cement augmentation. This study suggests that although cement augmentation appears to have superior pullout force, the novel pedicoplasty technique offers promise as a viable biological revision option for the management of failed pedicle screws compared with the option of standard upsized screws in a cadaveric model. These findings will ultimately need to be further assessed in a clinical setting.


Assuntos
Parafusos Pediculares , Humanos , Vértebras Lombares/cirurgia , Cimentos Ósseos , Osso e Ossos , Fenômenos Biomecânicos , Cadáver
6.
Global Spine J ; : 21925682231151924, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36645101

RESUMO

STUDY DESIGN: Retrospective database analysis. OBJECTIVES: To study postoperative complication rates following anterior cervical discectomy and fusion (ACDF) in patients with Ehlers-Danlos syndrome (EDS) compared with patients without EDS. METHODS: The Mariner database was utilized to identify patients with EDS undergoing one or two level anterior cervical discectomy and fusion (ACDF). Postoperative short-term outcomes assessed included medical complications, readmissions, and ED-visits within 90 days of surgery. Additionally, surgical complications including wound complications, surgical site infection, one- and two-year anterior revision along with posterior revision, pseudarthrosis, and hardware failure within 2 years were assessed. Multivariate logistic regression was used to adjust for demographic variables, comorbidities and number of levels operated on. RESULTS: The present study identified 533 patients in the EDS group and 2634 patients in the matched control group. EDS patients undergoing ACDF are at an increased risk for 90-day major medical complications (OR 3.31; P < .001). EDS patients were also found to be associated with surgical complications including wound complications (OR 2.94; P < .001), surgical site infection (OR 8.60; P < .001) within 90 days, pseudarthrosis (OR 2.33; P < .001), instrument failure (OR 4.03; P < .001), anterior revision (OR 22.87; P < .001), and posterior revision (OR 3.17; P < .001) within 2 years. CONCLUSIONS: EDS is associated with higher rates of both medical and surgical complications following ACDF. Spine surgeons should be cognizant of the increased risks in this population to provide appropriate preoperative counseling and enhanced perioperative medical management.

7.
Clin Orthop Surg ; 14(1): 105-111, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35251547

RESUMO

BACKGROUND: The use of translaminar screws may serve as a viable salvage method for complicated cases. To our understanding, the study of the feasibility of translaminar screw insertion in the actual entire subaxial cervical spine has not been carried out yet. The purpose of this study was to report the feasibility of translaminar screw insertion in the entire subaxial cervical spine. METHODS: Eighteen cadaveric spines were harvested from C3 to C7 and 1-mm computed tomography (CT) scans and three-dimensional reconstructions were created to exclude any bony anomaly. Thirty anatomically intact segments were collected (C3, 2; C4, 3; C5, 3; C6, 8; and C7, 14), and randomly arranged. Twenty-one segments were physically separated at each vertebral level (group S), while 9 segments were not separated from the vertebral column and left in situ (group N-S). CT measurement of lamina thickness was done for both group S and group N-S, and manual measurement of various length and angle was done for group S only. Using the trajectory proposed by the previous studies, translaminar screws were placed at each level. Screw diameter was the same or 0.5 mm larger than the proposed diameter based on CT measurement. Post-insertion CT was performed. Cortical breakage was checked either visually or by CT. RESULTS: When 1° and 2° screws of the same size were used, medial cortex breakage was found 13% and 33% of the time, respectively. C7 was relatively safer than the other levels. With larger-sized screws, medial cortex breakage was found in 47% and 46% of 1° and 2° screws, respectively. There were no facet injuries due to the screws in group N-S. CONCLUSIONS: Translaminar screw insertion in the subaxial cervical spine is feasible only when the lamina is thick enough to avoid any breakage that could lead to further complications. The authors do not recommend inserting translaminar screws in the subaxial cervical spine except in some salvage cases in the presence of a thick lamina.


Assuntos
Parafusos Ósseos , Vértebras Cervicais , Cadáver , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Estudos de Viabilidade , Humanos , Tomografia Computadorizada por Raios X/métodos
8.
J Med Internet Res ; 24(2): e31146, 2022 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-35138261

RESUMO

BACKGROUND: Psychiatry has long needed a better and more scalable way to capture the dynamics of behavior and its disturbances, quantitatively across multiple data channels, at high temporal resolution in real time. By combining 24/7 data-on location, movement, email and text communications, and social media-with brain scans, genetics, genomics, neuropsychological batteries, and clinical interviews, researchers will have an unprecedented amount of objective, individual-level data. Analyzing these data with ever-evolving artificial intelligence could one day include bringing interventions to patients where they are in the real world in a convenient, efficient, effective, and timely way. Yet, the road to this innovative future is fraught with ethical dilemmas as well as ethical, legal, and social implications (ELSI). OBJECTIVE: The goal of the Ethics Checklist is to promote careful design and execution of research. It is not meant to mandate particular research designs; indeed, at this early stage and without consensus guidance, there are a range of reasonable choices researchers may make. However, the checklist is meant to make those ethical choices explicit, and to require researchers to give reasons for their decisions related to ELSI issues. The Ethics Checklist is primarily focused on procedural safeguards, such as consulting with experts outside the research group and documenting standard operating procedures for clearly actionable data (eg, expressed suicidality) within written research protocols. METHODS: We explored the ELSI of digital health research in psychiatry, with a particular focus on what we label "deep phenotyping" psychiatric research, which combines the potential for virtually boundless data collection and increasingly sophisticated techniques to analyze those data. We convened an interdisciplinary expert stakeholder workshop in May 2020, and this checklist emerges out of that dialogue. RESULTS: Consistent with recent ELSI analyses, we find that existing ethical guidance and legal regulations are not sufficient for deep phenotyping research in psychiatry. At present, there are regulatory gaps, inconsistencies across research teams in ethics protocols, and a lack of consensus among institutional review boards on when and how deep phenotyping research should proceed. We thus developed a new instrument, an Ethics Checklist for Digital Health Research in Psychiatry ("the Ethics Checklist"). The Ethics Checklist is composed of 20 key questions, subdivided into 6 interrelated domains: (1) informed consent; (2) equity, diversity, and access; (3) privacy and partnerships; (4) regulation and law; (5) return of results; and (6) duty to warn and duty to report. CONCLUSIONS: Deep phenotyping research offers a vision for vastly more effective care for people with, or at risk for, psychiatric disease. The potential perils en route to realizing this vision are significant; however, and researchers must be willing to address the questions in the Ethics Checklist before embarking on each leg of the journey.


Assuntos
Lista de Checagem , Psiquiatria , Inteligência Artificial , Comitês de Ética em Pesquisa , Humanos , Consentimento Livre e Esclarecido , Privacidade
9.
Spine (Phila Pa 1976) ; 47(3): 252-260, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34310537

RESUMO

STUDY DESIGN: Retrospective, multicenter chart, and radiologic review. OBJECTIVE: To present the first case series of bone tumors of the spine surgically reconstructed with a new custom, fully radiolucent, polyetheretherketone/carbon fiber (PEEK/CF) vertebral body replacement (VBR) integrated system. SUMMARY OF BACKGROUND DATA: Surgical resections of spinal tumors result in large defects and local recurrence remains a concern. Current titanium-based implants adversely affects postoperative imaging, directly affects ability to identify tumor recurrence, and for delivery of radiotherapy treatments. PEEK/CF spinal implants allows for improved tumor surveillance, precise pre-radiation Computed Tomography planning, and reduces interference with post-reconstructive adjuvant radiotherapy. METHOD: Thirteen patients with spinal tumors underwent vertebral body resection and reconstruction with an integrated, fully radiolucent, custom PEEK/CF vertebral body replacement, and radiolucent posterior PEEK/CF screw-rod system and/or radiolucent anterior PEEK/CF plate system. Clinical and radiographic data were tabulated. Need for adjuvant radiotherapy determined based on final tissue histology and extent of surgical margins. Postoperative surveillance imaging were reviewed for local tumor recurrence. RESULTS: The ability to integrate the PEEK/CF VBR connected to either the posterior screw-rod system, or anterior plate system provided immediate stability. The VBR was placed directly on cancellous vertebral body surface in 46.2% of cases. Loosening of the distal, or proximal, aspect of posterior system was seen in 15.4% of cases. There was no clinical or radiographic evidence of VBR migration and subsidence at latest follow up. Local recurrence occurred in one (7.7%) patient. CONCLUSION: This is the first series to describe the use of a fully-radiolucent, integrated, PEEK/CF implant system for spinal tumor reconstruction. The use of a PEEK/CF VBR system integrated to either the anterior plate, or posterior screw-rod system is feasible and allows for superior postoperative surveillance imaging and effective delivery of postoperative adjuvant radiotherapy.Level of Evidence: 4.


Assuntos
Neoplasias da Coluna Vertebral , Corpo Vertebral , Benzofenonas , Parafusos Ósseos , Fibra de Carbono , Humanos , Cetonas , Polietilenoglicóis , Polímeros , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/cirurgia
10.
Spine (Phila Pa 1976) ; 47(4): 317-323, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34593732

RESUMO

STUDY DESIGN: Prospective cohort study. OBJECTIVE: The aim of this study was to 1) determine postural stability and spatiotemporal gait parameters and 2) characterize dynamic stability and variances in angular momentum (AM) of preoperative cervical spondylotic myelopathy (CSM) patients compared with healthy controls. SUMMARY OF BACKGROUND DATA: CSM is the most common cause of spinal cord dysfunction in the world and can lead to significant functional deficits including proprioception and gait disturbances. Biomechanical feedback mechanisms compensating for these deficits, specifically AM regulation, have remained largely unexplored. METHODS: Fifty-six subjects: 32 preoperative Nurick grade 2 or 3 CSM patients and 24 controls were included. Standing balance trials were performed on a single force plate, while walking trials were conducted at self-selected pace over a 15 m runway and a series of five force plates. All trials were recorded with three-dimensional motion analysis cameras and gait modeling software was utilized to calculate stability, spatiotemporal gait parameters, and joint kinematics. RESULTS: Tilted ellipse area, a measure of center of pressure variance and postural stability, was significantly greater among CSM patients (847.54 ±â€Š764.33 mm2vs. 258.18 ±â€Š103.35 mm2, P < 0.001). These patients had two times as much variance medial-lateral (72.12 ±â€Š51.83 mm vs. 29.15 ±â€Š14.95 mm, P = 0.001) and over three times as much anterior-posterior (42.25 ±â€Š55.01 mm vs. 9.17 ±â€Š4.83 mm, P = 0.001) compared with controls. Spatiotemporal parameters indicated that the CSM patients tending to have slower, shorter, and wider gait compared with controls, while spending greater amount of time in double support. Compensatory AM among CSM patients was significantly increased in all three anatomic planes, where whole-body AM was approximately double that of controls (0.057 ±â€Š0.034 vs. 0.023 ±â€Š0.006), P < 0.001). CONCLUSION: Preoperative CSM patients showed significant alterations in spatiotemporal gait parameters and postural stability compared with controls, consistent with prior literature. Likewise, angular momentum analysis demonstrates that these patients have globally increased body excursion to maintain dynamic balance.Level of Evidence: 3.


Assuntos
Doenças da Medula Espinal , Espondilose , Vértebras Cervicais/cirurgia , Marcha , Humanos , Estudos Prospectivos , Espondilose/cirurgia , Resultado do Tratamento
11.
Spine J ; 21(12): 2104-2111, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34062224

RESUMO

BACKGROUND CONTEXT: Complex spinal reconstructions involving corpectomies, or osteotomies, place spinal implants at extremely high stresses that can lead to pseudoarthrosis and ultimately to rod failure, resulting in revision surgery. Current clinical options to increase the biomechanical strength of a construct include increasing rod diameter, changing rod material, or placing an additional satellite/outrigger rod on a standard two rod construct. Fundamentally, all of these constructs still rely on two longitudinal rods across the reconstruction site and are therefore at risk for rod fracture and loss of alignment. Initially described in 2006, the Dual Construct was developed to address this limitation by utilizing four distinct mechanically independent rods, which allowed for the creation of two separate, and distinct, constructs within each patient. Although there is early clinical evidence to support its efficacy, this is the first biomechanical study to compare the Dual Construct to the two-rod and two-rod with satellite configurations in a cadaveric study. PURPOSE: To assess the biomechanical impact of the Dual Construct technique to traditional two-rod and two-rod with satellite rod construct in a cadaveric model. STUDY DESIGN/SETTING: Biomechanical cadaveric study METHODS: Nine fresh-frozen human cadaveric spines (6 males, 3 females, 56 year +/- 9 years) from T9-pelvis were instrumented and tested utilizing all three configurations including two-rod construct, two-rod with satellite construct, and the Dual Construct technique. Biomechanical testing order of the various constructs was randomized to reduce potential effects of order bias. Strain gauges were placed in both the coronal and sagittal planes of the rods to track the strains during flexion-extension and lateral bending while undergoing range of motion testing. Testing was performed using pure-moment flexibility testing protocols. RESULTS: In flexion-extension, the resultant strain in the two-rod construct was an average 600±228 microstrain, the two-rod with satellite rod strain averaged 603±237 microstrain, and the Dual Construct averaged 403±149 microstrain. In lateral bending, the resultant strain in the two-rod construct was an average of 266±134 microstrain, the satellite rod strain was an average of 310±158 microstrain, and the Dual Construct averaged 118±51 microstrain. In both flexion extension and lateral bending, a significant reduction in strain was observed between the Dual Construct condition compared to both the two-rod and satellite configurations. No significant difference was found between the two-rod and two-rod with satellite rod configurations. CONCLUSIONS: The increase in load sharing significantly decreases the strain experienced across the Dual Construct compared to traditional two-rod and two-rod with satellite constructs. Global rod strains on primary rods cannot be reduced by simply increasing the number of satellite rods, but can only be reduce by increasing the actual number of primary rods.


Assuntos
Fusão Vertebral , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Coluna Vertebral
12.
Neuroimage ; 238: 118210, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34062266

RESUMO

Smaller, more affordable, and more portable MRI brain scanners offer exciting opportunities to address unmet research needs and long-standing health inequities in remote and resource-limited international settings. Field-based neuroimaging research in low- and middle-income countries (LMICs) can improve local capacity to conduct both structural and functional neuroscience studies, expand knowledge of brain injury and neuropsychiatric and neurodevelopmental disorders, and ultimately improve the timeliness and quality of clinical diagnosis and treatment around the globe. Facilitating MRI research in remote settings can also diversify reference databases in neuroscience, improve understanding of brain development and degeneration across the lifespan in diverse populations, and help to create reliable measurements of infant and child development. These deeper understandings can lead to new strategies for collaborating with communities to mitigate and hopefully overcome challenges that negatively impact brain development and quality of life. Despite the potential importance of research using highly portable MRI in remote and resource-limited settings, there is little analysis of the attendant ethical, legal, and social issues (ELSI). To begin addressing this gap, this paper presents findings from the first phase of an envisioned multi-staged and iterative approach for creating ethical and legal guidance in a complex global landscape. Section 1 provides a brief introduction to the emerging technology for field-based MRI research. Section 2 presents our methodology for generating plausible use cases for MRI research in remote and resource-limited settings and identifying associated ELSI issues. Section 3 analyzes core ELSI issues in designing and conducting field-based MRI research in remote, resource-limited settings and offers recommendations. We argue that a guiding principle for field-based MRI research in these contexts should be including local communities and research participants throughout the research process in order to create sustained local value. Section 4 presents a recommended path for the next phase of work that could further adapt these use cases, address ethical and legal issues, and co-develop guidance in partnership with local communities.


Assuntos
Imageamento por Ressonância Magnética/ética , Neuroimagem/ética , Países em Desenvolvimento , Ética em Pesquisa , Humanos
14.
Clin Sports Med ; 40(3): xi-xii, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34051949
16.
Clin J Sport Med ; 31(3): e150-e160, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31842055

RESUMO

OBJECTIVES: The Ice Hockey Summit III provided updated scientific evidence on concussions in hockey to inform these 5 objectives: (1) describe sport related concussion (SRC) epidemiology; (2) classify prevention strategies; (3) define objective, diagnostic tests; (4) identify treatment; and (5) integrate science and clinical care into prioritized action plans and policy. METHODS: Our action plan evolved from 40 scientific presentations. The 155 attendees (physicians, athletic trainers, physical therapists, nurses, neuropsychologists, scientists, engineers, coaches, and officials) voted to prioritize these action items in the final Summit session. RESULTS: To (1) establish a national and international hockey database for SRCs at all levels; (2) eliminate body checking in Bantam youth hockey games; (3) expand a behavior modification program (Fair Play) to all youth hockey levels; (4) enforce game ejection penalties for fighting in Junior A and professional hockey leagues; (5) establish objective tests to diagnose concussion at point of care; and (6) mandate baseline testing to improve concussion diagnosis for all age groups. CONCLUSIONS: Expedient implementation of the Summit III prioritized action items is necessary to reduce the risk, severity, and consequences of concussion in the sport of ice hockey.


Assuntos
Traumatismos em Atletas , Concussão Encefálica , Hóquei , Traumatismos em Atletas/diagnóstico , Traumatismos em Atletas/epidemiologia , Traumatismos em Atletas/prevenção & controle , Concussão Encefálica/diagnóstico , Concussão Encefálica/epidemiologia , Concussão Encefálica/prevenção & controle , Congressos como Assunto , Hóquei/lesões , Humanos , Incidência
17.
Neurosurg Focus ; 49(5): E17, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33130619

RESUMO

OBJECTIVE: Current guidelines do not specify timing for management of acute spinal cord injury (aSCI) due to lack of high-quality evidence supporting specific intervals for intervention. Randomized prospective trials may be unethical. Nonetheless, physicians have been sued for delays in diagnosis and intervention. METHODS: The authors reviewed both the medical literature supporting the guidelines and the legal cases reported in the Westlaw and Lexis Advance databases from 1972 to 2018 resulting in awards or settlements, to identify whether surgeons are vulnerable to litigation despite the existence of guidelines not mandating specific timing of care. RESULTS: Timing of intervention was related to claims in 59 (36%) of 163 cases involving SCI. All 22 trauma cases identified cited timing of intervention, sometimes related to delayed diagnosis, as a reason for the lawsuit. The mean award of 10 cases in which the plaintiffs' awards were disclosed was $4,294,384. In the majority of cases, award amounts were not disclosed. CONCLUSIONS: Because conduct of a prospective, randomized trial to investigate surgical timing of intervention for aSCI may not be achievable, evidence-based guidelines will be unlikely to mandate specific timing. Nonetheless, surgeons who unreasonably delay intervention for aSCI may be at risk for litigation due to treatment delay. This is increasingly likely in an environment where "complete" SCI is difficult to verify. SCI may at some point be recognized as a surgical emergency, as brain injury generally is, despite a lack of prospective randomized trials supporting this implementation, challenging the feasibility of the US trauma infrastructure to provide care for these patients.


Assuntos
Traumatismos da Medula Espinal , Cirurgiões , Fidelidade a Diretrizes , Humanos , Estudos Prospectivos , Traumatismos da Medula Espinal/cirurgia , Coluna Vertebral
18.
PLoS One ; 15(10): e0240162, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33064732

RESUMO

It has been documented that up to 22% of all soccer injuries are concussions. This is in part due to players purposely using their head to direct the ball during play. To provide a more complete understanding of head trauma in soccer athletes, this study characterized the effects of four soccer ball characteristics (size, inflation pressure, mass, velocity) on the resulting peak impact force as it relates to the potential for incurring neurophysiological changes. A total of six hundred trials were performed on size 4 and 5 soccer balls as well as a novel lightweight soccer ball. Impact force was measured with a force plate and ball velocity was determined using motion capture. These data were used, in conjunction with dimensional analysis to relate impact force to ball size, mass, velocity, and pressure. Reasonable reductions in allowable ball parameters resulted in a 19.7% decrease in peak impact force. Adjustments to ball parameters could reduce a high cumulative peak translational acceleration soccer athlete down into a previously defined safer low loading range. In addition, it was noted that water absorption by soccer balls can result in masses that substantially increase impact force and quickly surpass the NCAA weight limit for game play. Additional research is required to determine whether varying soccer ball characteristics will enable soccer players to avoid persistent neurophysiological deficits or what additional interventions may be necessary and the legal implications of these data are discussed.


Assuntos
Aceleração/efeitos adversos , Traumatismos em Atletas/prevenção & controle , Concussão Encefálica/prevenção & controle , Futebol/lesões , Estresse Mecânico , Traumatismos em Atletas/etiologia , Fenômenos Biomecânicos , Concussão Encefálica/etiologia , Humanos , Modelos Biológicos
19.
Stem Cell Reports ; 15(4): 804-810, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33007202

RESUMO

We report findings from a new survey of US public attitudes toward human-animal chimeric embryo (HACE) research, designed to compare with recently reported Japanese survey data. We find that 59% of the US public can personally accept the process of injecting human induced pluripotent stem cells into genetically modified swine embryos and having human tissues produced in a pig's body transplanted into a human. This is greater acceptance than in Japan, and there is even strong acceptance among those with strong religious affiliations and who self-identify as conservatives. We argue that strong public support for HACE research, as well as the emerging literature suggesting that humanization of research animals is very unlikely, should compel the NIH to lift its current moratorium on HACE research.


Assuntos
Quimera/fisiologia , Opinião Pública , Pesquisa , Animais , Humanos , Inquéritos e Questionários , Estados Unidos
20.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...